Synopsis
- ficalib [options] [-i|--input <inputs>] [-o|--output <outputs>]
Description
- The purpose of this program is to do various calibration steps on the input images, including mosaic frame joining, generic overscan corrections, bias and (exp. time scaled) dark subtraction and flat field corrections.
Options:
General options:
- -h, --help
- Gives general summary about the command line options.
- --long-help
- Gives a detailed list of command line options.
- --version
- Gives some version information about the program.
- -i, --input <inputs>
- List of input images (up to the next option).
- -o, --output <outputs>
- List of output images (up to the next option).
- -r, --rewrite-output-name '[<from>|]<to>'
- Rewrite the output file names according to the rule specified by the argument of this switch. The <to> part must contain a single asterix (*) that is replaced by the original file name or, if the <from> part is specified and it can be matched by the filename, the appropriate part of the filename is written to the output filename. For instance, '*.fits|*.calib.fits' will replace the `fits` extension to `calib.fits` if the original filename has a fits extension, otherwise, concatenates the `calib.fits` as an extension to the filename. Note that the <from> and <to> part must be separated by a vertical bar (the character used in UNIX shells for creating pipes), therefore either this character must be escaped or put into quotation marks (according to the current shell). If the -o|--output list of filenames are not, but this argument is specified, the list of original output files will be the same as the list of input filenames.
Generic calibration options:
- --overscan <overscan>
- Specifications for overscan corrections (see also ``Overscan correction parameters below).
- --mosaic size=(<sx>,<sy>),(<mosaic section 1>),...
- Mosaic image topology specfications (see also ``Mosaic specification parameters below).
- -M, --input-mask <fits>
- Input mask file to co-add to output image.
- -B, --input-master-bias <bias>
- Master bias image (if any).
- -D, --input-master-dark <dark>
- Master dark image (if any).
- -F, --input-master-flat <flat>
- Master flat field image (if any).
- -s, --saturation <level>
- Saturation level.
- --leak-left-right, --leak-lower-upper, --leak-any
- Pixel/readout ``blooming direction.
- -g, --gain <gain>
- Nominal gain value.
- --gain-order <order>
- Spatial polynomial order to describe gain variations.
- --exptime-correction
- Do exposure time correction during dark subtraction.
- --no-exptime-correction
- Don't do any exposure time correction for darks.
- --no-clobber
- Don't overwrite existing calibrated images.
Output postprocessing and pixel depts:
- --image <x1>:<y1>:<x2>:<y2>
- Final image area.
- --trim
- Trim output to final image area.
- --no-trim
- Don't trim output to final image area (default).
- --post-scale <mean>
- Scale output to have the specified mean value.
- --post-multiply <factor>
- Multiply output image by the given factor.
- --data <spec>
- Output pixel data format specification.
- -b, --bitpix <bitpix>
- Standard FITS output bitpix value.
Overscan correction parameters:
- area=<x1>:<y1>:<x2>:<y2>
- Overscan area.
- spline
- Use cubic splines for overscan modelling.
- polynomial
- Use polynomials for overscan modelling.
- order=<order>
- Order for overscan variation (zero: constant).
- iterations=<n>
- Number of iterations for rejecting overscan outliers.
- sigma=<s>
- Overscan outlier limit in units of stddev.
Other corrections:
- --horizontal-stripe-removal
- Remove horizontal stripes.
Mosaic specification parameters:
- size=(<xsize>,<ysize>)
- Vertical and horizontal dimensions of the final image.
- name=<extension name>
- FITS extenison name of the given mosaic section.
- offset=(<x0>,<y0>)
- Offset of the given mosaic section in the final image.
- image=(<x1>:<y1>:<x2>:<y2>)
- Trim area of the given mosaic section.
- overscan=(<overscan>)
- Overscan parameters for the given mosaic section, in the same syntax and format as used after ``--overscan.